Q Lisa HCV Elisa
Q Lisa HCV Elisa

Q Lisa HCV Elisa

MOQ : 1 Piece

Q Lisa HCV Elisa Specification

  • Frequency
  • Single-use assay
  • Storage Instructions
  • Store at 2-8C, protect from light
  • Features
  • High sensitivity and specificity, easy-to-use kit format, reliable results, suitable for routine screening
  • Function
  • HCV Antibody Screening
  • Measurement Range
  • Qualitative (Presence or absence of HCV antibodies)
  • Accuracy
  • High (meets standard quality and performance criteria)
  • Instruments Type
  • Immunoassay Kit
  • Usage Type
  • Medical Laboratory, Clinical Diagnosis
  • Shelf Life
  • Up to 12 months (when stored as recommended)
  • Equipment Type
  • ELISA Kit for HCV Detection
  • Material
  • High-quality plastic components and reagents
  • Condition
  • New
  • Technology
  • Enzyme Linked Immunosorbent Assay (ELISA)
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • No
  • Operating Type
  • Manual
  • Use
  • Detection of Hepatitis C Virus (HCV) antibodies in human serum or plasma
  • Dimension (L*W*H)
  • Standard Kit Size
  • Weight
  • Standard Kit Weight
  • Color
  • White (kit components and plate)
  • Intended Users
  • Diagnostic Laboratories, Hospitals
  • Sample Type
  • Human Serum/Plasma
  • Test Principle
  • Enzyme Immunoassay for qualitative detection
  • Number of Tests
  • 96 Tests/Kit
  • Kit Components
  • Microtiter plate, Controls, Conjugates, Substrate, Wash Buffer
  • Reading Time
  • Approximately 120 minutes
  • Detection Method
  • Sandwich ELISA
 

Q Lisa HCV Elisa Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 10 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About Q Lisa HCV Elisa



Spotlight your laboratory's diagnostic potential with the exclusive Q Lisa HCV Elisa kit, available for a limited time. This imposing, first-rate immunoassay offers matchless reliability in detecting all major HCV genotypes. Designed for professional use, its manual procedure provides high sensitivity and specificity, ensuring robust medical screening. The comprehensive kit includes a 96-well plate, high-quality reagents, and an instructions manual, all securely packaged. Experience easy setup and colorimetric results compatible with microtiter plate readers-perfect for clinical laboratories demanding accuracy, efficiency, and unmatched performance.

Versatile Usage & Application Areas

Q Lisa HCV Elisa finds application in a variety of diagnostic media, catering specifically to clinical laboratories and research centers focusing on infectious disease screening. It is designed for detecting Hepatitis C antibodies in human serum or plasma, ensuring high sensitivity across all major HCV genotypes. This ELISA kit excels in routine screening, batch testing, and clinical diagnosis, promoting confidence in results through matchless accuracy. Its flexibility in different laboratory environments makes it a preferred choice in HCV diagnostics.


Sample Policy, Domestic Market & Supply Details

Our Q Lisa HCV Elisa kit is offered under a transparent exchange policy, ensuring customer satisfaction for all clients across the domestic mar. List price quotations are available upon request, matching industry standards for value. With an unwavering supply ability, we serve laboratories and healthcare establishments throughout India promptly. Every kit arrives ready to use, meeting standardized regulations for clinical diagnostics, and backed by reliable domestic exchange support and clear storage guidelines to maintain matchless quality.


FAQ's of Q Lisa HCV Elisa:


Q: How does the Q Lisa HCV Elisa kit detect Hepatitis C antibodies?

A: The Q Lisa HCV Elisa uses an indirect enzyme immunoassay, where patient serum or plasma is screened for anti-HCV antibodies, producing a colorimetric change read at 450 nm using a microtiter plate reader.

Q: What benefits does this kit offer for clinical laboratories?

A: The kit provides high sensitivity and specificity, matchless accuracy, compatibility with standard microtiter plate readers, and is suitable for routine hepatitis C screening and batch testing.

Q: Where can the Q Lisa HCV Elisa kit be used effectively?

A: This kit is best suited for medical laboratories, hospital diagnostic centers, and research facilities requiring efficient and dependable HCV antibody detection.

Q: What is the typical sample volume and incubation time required?

A: Typically, 100 L of sample per well is required, with incubation times ranging from 60 minutes to 2 hours, depending on each specific protocol step as detailed in the kit insert.

Q: What guidelines should be followed for storage and handling?

A: The kit should be stored at 2-8C and protected from light. Strict adherence to recommended storage conditions maximizes shelf life and ensures optimal performance.

Q: Who is the intended user for this ELISA kit?

A: Professionally trained laboratory personnel with experience in immunoassay procedures should use this kit to ensure accurate and reliable results.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Elisa Category

QL 9600 Microplate Reader

QL 9600 Microplate Reader

Minimum Order Quantity : 1 Piece

Operating Type : Automatic

Storage Instructions : Keep in Clean and Dry Environment

Features : Touchscreen Interface, High Sensitivity, Userfriendly Operation

Use : ELISA, Biochemical and Enzymatic Analysis

Function : Absorbance Reading, Data Processing, Curve Fitting

RT 2100C

RT 2100C

Minimum Order Quantity : 1 Piece

Operating Type : Automatic

Storage Instructions : Keep in dry and dustfree area

Features : High Precision, Digital Display, Builtin Printer

Use : Clinical Laboratory, Research Applications

Function : ELISA Plate Reading, Data Output

Stat Fax 2600

Stat Fax 2600

Minimum Order Quantity : 1 Piece

Operating Type : Automatic

Storage Instructions : Store in Dry, DustFree Environment

Features : Programmable, Multiple Wash Modes, Automatic Plate Positioning, LCD Display

Use : Microplate Washing for ELISA and Immunoassays

Function : Automated Plate Washing

Stat Fax 4700

Stat Fax 4700

Minimum Order Quantity : 1 Piece

Operating Type : Other, Automatic, User Interface Driven

Storage Instructions : Store in dry, dustfree environment

Features : Builtin printer, Absorbance reading, Touchscreen display, Onboard software

Use : ELISA, Enzyme Immunoassays, Microplate Analysis

Function : Quantitative and Qualitative analysis of microplates



arrow