Q Lisa Dengue NSI
Q Lisa Dengue NSI

Q Lisa Dengue NSI

MOQ : 1 Piece

Q Lisa Dengue NSI Specification

  • Usage Type
  • Single Use Kit
  • Instruments Type
  • Immunoassay Test Kit
  • Accuracy
  • High (manufacturer specified)
  • Function
  • Dengue Diagnosis
  • Frequency
  • Single use per test
  • Measurement Range
  • Qualitative detection of Dengue NS1 Antigen
  • Shelf Life
  • 12-24 Months
  • Storage Instructions
  • Store at 2-8C
  • Features
  • High sensitivity, Rapid & Accurate Results
  • Equipment Type
  • ELISA Test Kit
  • Material
  • Plastic, Glass, Reagents
  • Condition
  • New
  • Technology
  • Enzyme Linked Immunosorbent Assay (ELISA)
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • No
  • Noise Level
  • Silent/Not Applicable
  • Operating Type
  • Manual
  • Use
  • Detection of Dengue NS1 Antigen in Human Serum/Plasma
  • Power Source
  • Not Applicable (Manual Kit)
  • Dimension (L*W*H)
  • Standard Kit Packaging
  • Weight
  • Approx. 500g (with packaging)
  • Color
  • White with multiple colored reagent vials
  • Sample Type
  • Human serum or plasma
  • Test Principle
  • Sandwich ELISA method
  • Incubation Time
  • Approx. 90 minutes total
  • Pack Size
  • 96 tests per kit
  • Intended User
  • Laboratory professionals/Healthcare practitioners
  • Kit Contents
  • Microtiter plate, conjugate, substrate, wash buffer, stop solution, positive and negative controls
  • Readout Method
  • Colorimetric (absorbance measured at 450 nm)
 

Q Lisa Dengue NSI Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 10 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About Q Lisa Dengue NSI



The Q Lisa Dengue NS1 is a top-rated ELISA Test Kit designed for the detection of Dengue NS1 antigen in human serum or plasma. This classic microwell strip plate format offers towering performance, with rapid, accurate results in just 60-75 minutes while using only 100L of sample. Hospitals, diagnostic laboratories, and research institutes can conveniently procure this virtuoso kit, complete with positive and negative controls and ready-to-use reagents. Promotion-worthy features include high sensitivity and a user-friendly design in portable packaging, ensuring consistent and reliable dengue diagnosis every time.

Versatile Usage and Application Areas

Q Lisa Dengue NS1 ELISA Kit is a single-use kit tailored for qualitative detection of Dengue NS1 antigen. Ideally suited for application in hospitals, diagnostic laboratories, and research institutes, its versatility extends to areas requiring high-precision, rapid diagnosis of dengue infection. The kit's easy-to-operate assay format and clear instructions promote efficient, reliable testing across locations aiming to mitigate dengue outbreaks swiftly.


Swift Supply and Delivery Process

Q Lisa Dengue NS1 kits are dispatched via FOB India, ensuring prompt arrival at the port of choice. With a robust supply ability, traders and suppliers maintain an optimal inventory to meet varying demand rates. Typical delivery time is streamlined-handover of the kits usually occurs within agreed schedules, supporting urgent public health requirements and facilitating unhindered access to critical testing solutions.


FAQ's of Q Lisa Dengue NSI:


Q: How does the Q Lisa Dengue NS1 ELISA Test Kit function?

A: This kit operates on the sandwich ELISA principle, detecting the presence of Dengue NS1 antigen in human serum or plasma through enzyme-linked immunoassay technology.

Q: What is the sample volume required for accurate results?

A: The Q Lisa Dengue NS1 kit requires only 100L of serum or plasma sample to deliver high-sensitivity and accurate qualitative results.

Q: When can I expect to receive results after initiating the test?

A: You can obtain rapid and reliable results within 60 to 75 minutes after starting the test, making it suitable for quick dengue screening.

Q: Where can this ELISA Kit be effectively utilized?

A: It's intended for use in hospitals, diagnostic laboratories, and research institutes, where precise and swift dengue detection is essential.

Q: What controls are included in the kit for quality assurance?

A: The kit is supplied with both positive and negative controls to ensure consistent test accuracy and reliable performance each time.

Q: How should the Q Lisa Dengue NS1 Kit be stored for maximum shelf life?

A: Store the kit at 2-8C as specified, allowing for an optimal shelf life of 12-24 months and preservation of reagent integrity.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Elisa Category

QL 9600 Microplate Reader

QL 9600 Microplate Reader

Minimum Order Quantity : 1 Piece

Portable : No

Noise Level : Low Noise

Use : ELISA, Biochemical and Enzymatic Analysis

Color : White/Grey

Storage Instructions : Keep in Clean and Dry Environment

Stat Fax 4700

Stat Fax 4700

Minimum Order Quantity : 1 Piece

Portable : Yes

Noise Level : Low

Use : ELISA, Enzyme Immunoassays, Microplate Analysis

Color : Black

Storage Instructions : Store in dry, dustfree environment

Stat Fax 2600

Stat Fax 2600

Minimum Order Quantity : 1 Piece

Portable : Yes

Noise Level : Low

Use : Microplate Washing for ELISA and Immunoassays

Color : Black/Blue (with Clear Cover)

Storage Instructions : Store in Dry, DustFree Environment

QL Lisa 4800 Microplate

QL Lisa 4800 Microplate

Minimum Order Quantity : 1 Piece

Portable : Yes

Noise Level : Low

Use : Microplate Washing in Laboratory

Color : White

Storage Instructions : Keep in clean, dry place



arrow